PTT-20260803-WA0003
Aug 03, 2026 22:42
· 1:25
· English
· Whisper Turbo
· 2 Wasemaji
Rekodi hii inamalizika 23 siku.
Kufugwa kwa ajili ya uhifadhi wa kudumu →
Kuonyesha tu
0:00
S…
Speaker 1 (PTT-20260803-WA0003)
Ali Askar 070,
0:02
S…
Speaker 1 (PTT-20260803-WA0003)
a bone defect is noted within the right parietal bone with
0:06
S…
Speaker 1 (PTT-20260803-WA0003)
a gapping linear fracture extending from this
0:10
bone defect towards the right temporal bone,
0:13
S…
Speaker 2 (PTT-20260803-WA0003)
full stop.
0:14
S…
Speaker 1 (PTT-20260803-WA0003)
This
0:19
S…
Speaker 1 (PTT-20260803-WA0003)
is associated with gliotic
0:23
S…
Speaker 1 (PTT-20260803-WA0003)
changes within the underlying left,
0:29
S…
Speaker 1 (PTT-20260803-WA0003)
right,
0:31
S…
Speaker 1 (PTT-20260803-WA0003)
sorry, right parietal
0:35
S…
Speaker 1 (PTT-20260803-WA0003)
temporal bone.
0:41
S…
Speaker 1 (PTT-20260803-WA0003)
Full stop.
0:41
S…
Speaker 1 (PTT-20260803-WA0003)
Multiple calcifications are also noted within this
0:45
S…
Speaker 1 (PTT-20260803-WA0003)
parietal lobe.
0:46
S…
Speaker 1 (PTT-20260803-WA0003)
Full stop.
0:47
S…
Speaker 1 (PTT-20260803-WA0003)
X -Vecu dilatation of the right lateral ventricle is noted measuring
0:51
S…
Speaker 1 (PTT-20260803-WA0003)
approximately 2 .5
0:56
S…
Speaker 1 (PTT-20260803-WA0003)
cm at the level of body.
0:57
S…
Speaker 2 (PTT-20260803-WA0003)
Full stop.
0:57
S…
Speaker 1 (PTT-20260803-WA0003)
Third ventricle is also dilated measuring 1 .8
1:02
S…
Speaker 1 (PTT-20260803-WA0003)
cm.
1:02
S…
Speaker 2 (PTT-20260803-WA0003)
Full stop.
1:03
S…
Speaker 1 (PTT-20260803-WA0003)
Fourth ventricle is not significantly dilated.
1:05
S…
Speaker 1 (PTT-20260803-WA0003)
Full stop.
1:06
S…
Speaker 1 (PTT-20260803-WA0003)
Conclusion CT features are of a large
1:09
S…
Speaker 1 (PTT-20260803-WA0003)
Right parietal bone defect with underlying parietal temporal lobe
1:14
S…
Speaker 1 (PTT-20260803-WA0003)
gliosis and ex -recu dilatation of the right lateral ventricle
1:18
S…
Speaker 1 (PTT-20260803-WA0003)
as described.
1:18
S…
Speaker 2 (PTT-20260803-WA0003)
Full stop.
1:19
S…
Speaker 1 (PTT-20260803-WA0003)
Correlation with baseline imaging slash medical records is suggested.
1:23
S…
Speaker 2 (PTT-20260803-WA0003)
Full stop.
Nakala hii ilitokezwa na AI (utambuaji wa usemi wa kiaya). Inaweza kuwa na makosa Équipe dhidi ya sauti ya awali kwa utumizi wa kuchambua. Sera ya AI
Muhtasari
Bonyeza muhtasari ili kutokeza muhtasari wa AI juu ya nakala hii.
Kutoa muhtasari...
Uliza Maswali Kuhusu Mpito Huu
Uliza jambo lolote kuhusu nakala hii ya kitabu KULEA ile nitakayopata sehemu zinazofaa na majibu.